The cradle can sit on a desktop or be wall-mounted, whichever is more convenient. The cradle receives data from the scanner via the antenna on the side of the cradle. The cradle then transmits that data to the host device via an attached cable. It also acts as a holder for the scanner. The cradle has a charge status indicator light that shows the status of the battery charging Refer to Table on page Below is an index of Quick Startup Instructions to help get you up and going quickly.
These instructions are also on the back cover of this guide for easy reference. The index is listed in a step by step order beginning with step 1, Setting up the System.
If an item has multiple pages referenced, the most important reference is in bold. Below are commonly used programming bar codes.
You can cut this page out of the guide, or make a copy of the bar codes using a high quality copying machine. This chapter covers the procedures for setting up the RF scanner and its accessories. Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call one of the telephone numbers listed in the section Symbol Support Center on page xi.
It is the approved shipping container and should be used if you ever need to return your equipment for servicing. The basic steps to set up the cradle are listed below and described in more detail in the following sections. With some host types, the scanner is unable to answer host terminal polls if the appropriate host type is not selected. This may result in an error message generated by the host.
To correct this situation, select the proper parameter set and initialize the host terminal. See Chapter 5, Parameter Menus for more information. Make sure all host devices are powered down. Plug the other end of the cable into the COM1 connector on the cradle.
Power port. Connect the power connector of the power supply into the Power port on the cradle. Connect the appropriate line cord to the power supply and into an AC receptacle. The indicator light on the cradle blinks, signifying successful power-up. Before power is provided to the cradle step 6 , the following steps must be completed.
The Synapse cable must be connected to the cradle step 2 AND the flying power lead plugged in step 4. If the cables are not connected in this sequence, the Synapse Interface Adapter will not operate properly.
Connect the Synapse cable to the cradle see Figure on page Connect the other end of the Synapse cable to the Synapse Interface adapter. The Synapse cable has a flying power lead. Connect this lead to the receptacle in the Synapse Interface adapter, as shown in Figure See the Synapse guide for details. Connect the Synapse Interface adapter to the host. Connect the power supply to the cradle see Figure Scan the appropriate Synapse bar codes to set up the Synapse cable for your specifications.
Rotate the antenna to the vertical position. Before wall-mounting the cradle, the scanner support tab must be changed from the deskmount position to the wall-mount position. Lift the scanner support tab out of the top part of the cradle and replace it in the wall-mount position.
Seat the cables from the bottom of the cradle in the grooves along the length of it so that the bottom of the cradle is smooth. Place the cradle over the screw heads and slide down until it fits into place.
Slight pressure upwards should not move the cradle. Position the antenna vertically pointing toward the ceiling. Place the scanner in the cradle. Note: If the cradle is attached to a new host, re-scan the pairing bar code.
Scan the pairing bar code on the top of the cradle. This 15 mil bar ode,c packaged with the cradle, can be scanned by the P ALR at a distance of approximately two feet from the cradle. Once the base is detected, information is exchanged addressing, RF channels, etc.
Note: It may take up to 30 seconds for the scanner to search for the base during over-the-air pairing. To reduce the pairing time, place the scanner in the cradle. After the exchange is complete, the scanner and cradle are paired. The pairing of a scanner to a cradle is one-to-one. Only one scanner can be paired to a cradle at any point in time. To pair a scanner to a different cradle, scan its pairing bar code located on the top of the cradle.
The RF scanner and cradle are equipped with a 2. In addition to being a 2-way RF transmitter, the cradle is a battery charger and should be mounted in an accessible location like on a table or desktop. For optimum RF performance, especially in difficult environments, mount the cradle on a wall as high as possible. If you operate your scanner or cradle in close proximity to a Spectrum24 device, maintain a buffer of 3 feet or greater between the transmitters.
If a scanner or cradle is less than 3 ft. As a rule of thumb, the Cordless systems operated closest to Spectrum24 devices should use these channels. After channels 81, 82 and 83, the next best channels to use are 60 through 80; the higher the channel the better.
See Appendix C, Radio Channels for a list of available radio channels per country. Cordless Phaser scanners support up to 82 communication channels. Not all channels are available in all countries. Refer to Appendix C, Radio Channels for more information. The scanner attempts 4 RF Retries default but can be programmed to attempt up to 8. Depending on your particular RF environment, additional retries may cause your scanner transaction time to increase in the presence of heavy Spectrum24 traffic.
Set up the cradle as described in Setting Up the Cradle on page Insert the scanner into the cradle so that the nose of the scanner and tip of the handle seat into the receptacles.
The battery charges automatically. Note: For additional information on charging, see Table on page The cradle recharges batteries in the scanner only when the scanner is in the cradle. A scanner with a depleted battery starts charging immediately upon insertion into the cradle, whereas a scanner with a partially charged battery begins charging after approximately 15 minutes.
Note that the scanner can be removed from the cradle at any time. The cordless scanner is shipped from the factory with a default scan and transmit application. This application allows users to scan and view data, enter quantities, and manually enter alphanumeric data. When the unit is powered up, it displays the system start-up banner. When the scanner is powered up or reset, the system banner appears as follows:. After a few seconds, the System Banner is replaced by the system initialization screen.
If a Synapse cable is attached, the scanner automatically overrides the default settings. In this mode, scanned bar codes are automatically transmitted to the cradle and then the host in real time.
The default application also allows you to manually enter data if no bar code is present. By default, this feature is enabled. This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page If your entry exceeds 34 characters, the characters will scroll off the visible portion of the screen, but are retained for storage.
Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics.
For example, to manually enter 17ABF5 , do the following steps:. For more information, refer to Keypad Operation on page To eliminate repetitive scanning of identical items, you can enter a quantity prior to scanning a bar code.
This quantity entry feature can also be used when manually entering bar code data. Next, the bar code data entry screen reappears.
The scanner sends the bar code data to the host the keyed-in amount of times. For instance, if you type in a quantity of 6 then scan a bar code, the scanner sends that bar code data to the host six times as if the bar code had been scanned six times. A communication error occurs when the scanner, cradle or host fails to properly communicate.
The three-digit error code on the scanner screen indicates what type of communication problem occurred. Error code generally indicates the scanner is out of RF range, not properly paired to the base, or the base may have lost power. The cradle received the RF transmitted data, but the scanner did NOT receive a cradle's acknowledgment. The host and cradle are not communicating properly. If the RF transmitted data was NOT received by the cradle, move the scanner closer to the cradle to reestablish communication, then re-scan the bar code.
If the communication has been reestablished, the scanner will sound a good decode beep and no error beeps. Resume normal scanning. If the cradle received the RF transmitted data, but the scanner did NOT receive a cradle's acknowledgment, move the scanner closer to the cradle to reestablish communication, then re-scan the bar code. In this scenario data may have been transmitted to the host. If the cradle had previously sent data to the host, it will NOT pass this re-scanned data to the host.
For additional information see Optimizing RF Performance on page If the host and cradle are not communicating properly, insure the cabling is properly connected, baud rate is properly set, and correct COM port has been selected.
Enter the System Menu by scanning the bar code below or by entering a keypad sequence. Commonly used System Menu programming bar codes have been consolidated on page Below is the list of available options. Press the Up and Down arrow keys to scroll through them. Appendix C, Radio Channels. Control allows you to control your application, specifically, load new applications on your scanner, reset your default applications, etc.
You can load a new application or system code by either scanning the appropriate bar code or entering the appropriate keypad value as indicated on the display. When this screen displays, the scanner is ready to accept the download. On the PC Utility, initiate the download. After downloading is complete, the system menu is exited and the application initiated.
The default. Selecting Enable will enable this feature; Disable will disable. Place the scanner in the cradle before initiating the download from the PC Utility.
After the download is complete, the system menu is exited and the application initiates. In addition, power to the cradle must be cycled powered off then on before it will communicate with the scanner again. Note: You will automatically exit this message after 15 seconds. To enter this mode from an application outside of the System Menu, scan the bar code below. This enhances capability between bar code data and your host software, allowing you to program the scanner rather than modifying your host application.
The cordless scanner can be programmed via a cordless RF download or by scanning Scan generated programming bar codes. Scanner programming is saved in a setup file which can be distributed electronically Web site, floppy disk, E-mail, or fax. A copy of Scan is on the CD included with your scanner. Note: Advanced data formatting rules created with Scan are for use with the default application only and will not work with applications created with MCL-Designer.
To remove previously programmed ADF rules from the scanner, scan the bar code below. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. Symbol Technologies. All rights reserved. Contents About This Manual Introduction.
Set Up Introduction. Operation Introduction. Maintenance And Specifications Introduction. Parameter Menus Introduction. Contents Host Type. Contents Intercharacter Delay. A-3 Appendix B. Automatic Project Download Appendix C. C-1 Appendix D. Messages and Error Codes Introduction. D-1 Messages.
D-1 Communication Errors. D-2 Scanning Transmission Range. D-2 Index Feedback. Notational Conventions The following conventions are used in this document:. Service Information If you have a problem with your equipment, contact the Symbol Support Center for your region. Symbol Technologies Canada, Inc. Haus, 5.
Symbol Technologies S. Peonias, No. Warranty Symbol Technologies, Inc. General Except for the warranties stated above, Symbol disclaims all warranties, express or implied, on products furnished hereunder, including without limitation implied warranties of merchantability and fitness for a particular purpose. Figure Unless otherwise noted, the term Cradle refers to both versions of the cradle.
PRG Page 1. Unpacking Remove the scanner from its packing and inspect it for damage. Setting Up the Cradle The basic steps to set up the cradle are listed below and described in more detail in the following sections. Connecting to a Host With some host types, the scanner is unable to answer host terminal polls if the appropriate host type is not selected.
RS Connection 1. COM1 Power port Figure Ports on the Cradle 4. Power Supply Port. Set Up 7. Using A Synapse Cable 1. Synapse and Adapter Cable 5. An adapter cable is required. Wall Mounting Before wall-mounting the cradle, the scanner support tab must be changed from the deskmount position to the wall-mount position. Desk Mount Wall Mount Figure Scanner Support Tab 2. Cable Grooves Figure Placement of Cables. Set Up 3. Securing Cradle to Wall 5. To pair the scanner with the cradle: 1.
Coexistence in Spectrum24 Environments If you operate your scanner or cradle in close proximity to a Spectrum24 device, maintain a buffer of 3 feet or greater between the transmitters. Set Up Using the Cradle 1. Placing the Scanner into the Cradle 2. Chapter 3 Operation Introduction This chapter covers how to use the cordless Phaser scanner.
Default Application The cordless scanner is shipped from the factory with a default scan and transmit application. When the scanner is powered up or reset, the system banner appears as follows: Symbol Technologies Phaser RF. For fast integration, both the P and P support the Scan setup utility software, a convenient Microsoft Windows -based program that helps reduce your start-up time and costs for these scanners.
Enter is a more popular choice than Return. However, just because you use negative logic for one symbol does not force you to use negative logic for the other. View and Download Symbol P quick reference manual online. Ergonomically designed to minimize fatigue in scan-intensive applications, the P features a top-mounted keypad and display for effortless access and increased productivity.
Throughout the SoC has less than 64 bits. If your business applications demand cordless real-time data capture and transmission, demand the P scanners. JavaScript seems to be disabled in your browser. The warranty does not cover defects caused symbol pl alteration, modification, repair, misuse of product or physical abuse of product. International customers should contact the local Symbol office or support center. Symbol P product reference manual online tech support center.
The SMMUv3 specifies that input addresses are conceptually 64 bits. We do not take debi Update me with the latest news from Barcodes Symbol pl Designed with a comfortable forward-scanning pistol grip to minimize fatigue in scan-intensive applications, the scanners are available in keypad or keyless configurations. Of components that will allow you to be. Dear Suchit. XS X Eliminate repetitive scanning by Symbol P supports the other.
This Windows -based Advanced Data Formatting utility enables bar coded data to be. Each tookkit includes a suite of components that provides a unified software development framework with a wide range of functions for interfacing Zebra Scanners to user applications and solutions.
Scanner Charging Cradle charges your start-up time. Trust, high-performance wireless devices that helps reduce your industrial facility.
0コメント